Yj -F6 hospital equipment 12-inch multi-parameter ICU patient monitor

YJ-F6 hospital equipment 12 inch multi parameter ICU patientmonitorFeatures:12.1\'color TFT LED screen supports display Max.8 waveformsSuitable for monitoring adult, pediatric and neonatal patientDesigned without fan, characterized with&nbs

Featured Products

YJ-F6 hospital equipment 12 inch multi parameter ICU patientmonitor

Yj-F6 Hospital Equipment 12 Inch Multi Parameter ICU Patient Monitor

Features:
  • 12.1'color TFT LED screen supports display Max.8 waveforms
  • Suitable for monitoring adult, pediatric and neonatal patient
  • Designed without fan, characterized with no noise and lower consumption
  • Acoustic and visual alarm 
  • Analog SpO2 technology, against interference of ESU, motion & low infusion
  • Display mode: Standard, Large Font, Trend Table, Full lead ECG, Oxy CRG 
  • Drug calculation and titration table 
  • Pacemaker detection and Arrhythmia analysis 
  • Supporting large capacity of storage 
  • Isolated against defibrillation effect
  •  


  • Standard Configuration:
    3-lead or 5-lead ECG/HR, RESP, Dual TEMP, SpO2/PR, NIBP 
    Optional Configuration:
    2 IBP, Central Monitoring System, Touch screen, Printer, Trolley, Wall-mount

    Yj-F6 Hospital Equipment 12 Inch Multi Parameter ICU Patient Monitor
    Specification:
ECGLead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto
Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50 mm/s
ECG signal range:  ±12 mV (Gain × 0.25) Auto
ECG signal range:  ±6 mV
Accuracy: ±1bpm/ ±1%, whichever is greater
Resolution: 1 bpm
RESPMethod: Impedance between RA-LL, RA-LA
Gain: ×0.25, ×0.50, ×1, ×2
Respiration Rate: Adult: 0 ~ 120 BrPM;
 Neonatal / Pediatric: 0 ~ 150 BrPM
Resolution: 1 BrPM
Accuracy: ±2 bpm or ±2%, whichever is greater
Apnea Alarm: 10 ~ 40 s
NIBPMethod: Oscillometric
Measure mode: Manual, Auto, STAT
STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
Measure and Alarm Range: Adult:SYS:  40 ~ 280 mmHg,DIA:  10 ~ 220 mmHg ,MEAN:  20 ~ 240 mmHg
Static pressure accuracy: ±3mmHg
Resolution: 1mmHg
Accuracy: Maximum Mean error ±5mmHg           

 Maximum Standard deviation ≤8mmHg
Over pressure Protection: Dual protection via software & hardware
SPO2Measurement Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: 70% ~ 100%: ±2 %  
         40% ~ 69%, ±3 %;
         <39%, unspecified;
TEMPChannel: Dual-Channel, provide T1; T2; ΔT
Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF)
Resolution: 0.1ºCor 1ºF
Accuracy: ±0.1ºC(exclusive probe error)
PRMeasuring and Alarm Range: 20~300bpm
Accuracy: ±3bpm
Resolution: 1bpm

Light and portable, much clearer image and convenient to operate. YJ-U580 has an extra-long
battery life with over 8 hours of standby time and 4 hours of working time - useful for consultation in various environment of cities, towns, outdoor. A variety of charging to ensure the examination consultation under different environments.

Our company:
Yj-F6 Hospital Equipment 12 Inch Multi Parameter ICU Patient Monitor

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours