S1600 Medical portable human body inhalation ICU respiration respiration monitoring ventilator system

S1600 Medical Portable Human Inhalation ICU Respiratory Breathing Monitoring Ventilator SystemMain features: *Electric control and pneumatical driven *Applicable to both adults and children *10.4\'\' TFT LCD display screen *Multiple working mode and ventilation modes such as IPPV,A/C,SIMV,

Featured Products

S1600 Medical Portable Human Inhalation ICU Respiratory Breathing Monitoring Ventilator System
S1600 Medical Portable Human Inhalation ICU Respiratory Breathing Monitoring Ventilator System


Main features:

 *Electric control and pneumatical driven

 *Applicable to both adults and children

 *10.4'' TFT LCD display screen

 *Multiple working mode and ventilation modes such as IPPV,A/C,SIMV,SPONT/CPAP,MAUN

 *With alarming functions

 *With built-in spare power source,when outside power source goes off, back up power source starts to work

 

 Work condition:

 Gas source:O2

 Rated working pressure:280kpa~600kpa

 Power source: Voltage ~100V~240V

              Frequency:50/60HZ

 

Main parameters

Adjusting range of parameters:

Frequency:1 bpm ~ 100 bpm(

           SIMV mode:1 bpm~ 20 bpm

           Other modes: 4 bpm~ 100 bpm

Tinsp(inspiratory time):0s~ 6s(Except for SIMV mode,Respiratory ratio:4:1~1:8)

VT(Tidal volume) range: 0 mL ~ 1500 mL

PEEP: 0 cmH2O ~ 20 cmH2O  

CPAP: 0 cmH2O ~ 20 cmH2O

Adjusting range of O2 concentration: 45 %~100 %

 

Holding time(Inhalation platform /TIP): 0 ~ 3s(≤50 % inspiratory time)

SIGH adjusting range:1/100 ~ 5/100

Suffocation ventilation: OFF,5 s ~ 60 s

Pressure limit range:20cmH2O ~ 100 cmH2O

Ventilation volume under MAUA mode:>=25L/min

Max safety pressure<12.5Kpa

 

Monitoring parameters:

Frequency:0 /min ~ 100 /min

VT(Tidal volume):0 mL ~ 2000 mL

MV(Tidal volume/min):0 L/min ~ 99 L/min

Tube pressure:0 cmH2O ~ 100 cmH2O   

Concentration of inhaled oxygen:15 % ~ 100 %

 

Graphical display  

Tube pressure-time wave line                                                            

Air flow-time wave line

 

Alarming and protection function:

Alarm when AC power off

Alarm when spare power voltage getting low

Alarm when there's tidal volume

Alarm when ventilation volume too high or too low

Alarm when tube pressure too high or too low

Pressure limits

Alarm when concentration of Oxygen too high or too low

Alarm when suffocation occurs

Pressure safety relief valve<125cmH2O


Details:
S1600 Medical Portable Human Inhalation ICU Respiratory Breathing Monitoring Ventilator System


Company Information:

S1600 Medical Portable Human Inhalation ICU Respiratory Breathing Monitoring Ventilator System

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours