Patient Monitoring Devices Color TFT optional touch screen ICU Vital Signs Monitor
Main Features
1. 15 inch high resolution color TFT display, resolution: 1024*768
2. One level menu, easy to use
3. Parameters including ECG, RESP, SPO2 , NIBP, TEMP, Pulse Rate Maximum 720 hour graphic and tabular trends of all parameters
4. Built-in recorder and battery
5. Suitable for adult, pediatric, neonatal and vet use
6. 13 type Arrhythmia analysis, Multi-lead ECG Waveforms Display in phase, real time ST segment Analysis, Pacemaker detection, Drug calculation and titration
7. SPO2 can test for 0.1% weak
8. RA-LL impedance respiration
9. OxyCRG Dynamic View, Bed to Bed view and short Trend Coexist Display, nurse call system
10. Anti-ESU, anti- defibrillator
11. Capture dynamic waveforms
12. Touch screen is acceptable
13. Standard network interface, can connect to Central monitor system
14. Standard Configuration: ECG , Spo2 , PR , NIBP , RR , Temp
15. Optional: built-in printer, IBP, ETCO2, touch screen, wireless network, cart
ECG
Lead mode; I,II,III,AVR,AVL,AVF,V
Gain:X0.25,X0.5,X1,X2
Heart Rate:15-300BPM(Adult) 15-350BPM(Neonatal)
Resolution:1 BPM
Accuracy:+-1%
ST measurement Range:-2.0-+2.0mV
Accuracy:+-10%
Pacemaker:Yes
Sweep Speed:12.5 mm/s,25mm/s,50mm/s
Bandwidth:Diagnostic:0.05--130Hz
Monitor: 0.5--40Hz
Surgery: 1-20Hz
HR and Alarm Range
Adult: 15-300 bpm
Neo/Ped: 15-350 bpm
Accuracy: 1 bpm
CMRR
Monitor: >105 db
Operation: 105 db
Diagnosis: >85 db
Temperature
Measure Range:0-50C
Resolution:0.1C
Accuracy:+-0.1C
spO2
Measure Range:0-100%
Resolution:1%
Accuracy:2%(70-100%)
Pulse Rate:20-250BPM
Resolution:1BPM
Accuracy:+-3BPM
NIBP
Work mode:Manual,Automatic,Continuous
Unit:mmHg,Kpa
Measure Range:
Adult: SYS: 40-270mmHg
DIA: 10-210mmHg
MEAN:20-230mmHg
Pediatric SYS:40-200mmHg
DIA: 10-150mmHg
MEAN:20-165mmHg
Neonatal SYS:40-135mmHg
DIA:10-100mmHg
MEAN:20-110mmHg
Resolution:1mmHg
Accuracy:+-5mmHg
Pulse rate
Measure range: 20-300 BPM
Accuracy: ±2 BPM
Resolution: 1 BPM
IBP
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART: 0-300 mmHg
PA: -6-120 mmHg
CVP, RAP, LAP, ICP: -10-40 mmHg
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART: 0-300 mmHg
PA: -6-120 mmHg
CVP, RAP, LAP, ICP: -10-40 mmHg
Press sensor
Sensitivity: 5 uV/V/mmHg
Accuracy (no sensor); ±2%or1mmHg
Band width: Normal mode: DC~40Hz
Smooth mode: DC~12.5Hz
ETCO2
Measure range: 0% - 13%
Resolution: 1 mmHg
Accuracy : ±2 mmHg @ < 5.0% CO2 (at ATPS)
Respiration: 3 - 150 bpm
Depth of anesthesia (optional)
EEG sensitivity ±400μV
Noise <2μVp-p , <0.4μV RMS,1-250Hz
CMRR >100Db
Input impedance >50Mohm
Sample rate 2000 samples/sec.(14 bits equivalent)
CSI and update 0-100.Filter 6-42Hz,1 sec.update
EMG 0-100logarithmic.Filter75-85Hz,1sec.update
BS% 0-100%.filter 2-42 Hz,1 sec.update