China 12.1\\" 7-parameter medical hospital patient monitor

China 12.1" Multi-parameter Medical Hospital Patient Monitor CHM-K8000B12.1-inch high-resolution color TET LCD display.Thinner and lighter in design, convenient and portable for users.Real-time S-T segment analysis, pacemaker detection.Various interfaces: standard screen, trend screen, oxy CRG screen, NIBP list screen,

Featured Products

China 12.1" Multi-parameter Medical Hospital Patient Monitor 
CHM-K8000B

China 12.1
12.1-inch high-resolution color TET LCD display.
Thinner and lighter in design, convenient and portable for users.
Real-time S-T segment analysis, pacemaker detection.
Various interfaces: standard screen, trend screen, oxy CRG screen, NIBP list screen, big front screen.
3-level audio/visual alarms.
Efficient resistance to interference of defibrillator and HF knife.
Up to 400 groups NIBP list, 6000seconds, ECG waveform recall, 60 alarm event records recall, 7-day trend chart in storage.
Built-in rechargeable lithium battery, 2-hour working capability.
Wireless central monitoring system applicable to ICU/CCU/OR

Size: 12.1 inch
Weight: 5kg
Electrical Specification: 100-240v AC, 50/60Hz, Max Input Power: 70VA
Battery: 11.1V 2200mAh rechargeable lithium battery
Standard configuration: SpO2, PR, NIBP, ECG, RESP, TEMP
Optional Configuration: Nellcor SpO2, 2-IBP, ETCO2, Touch screen, Built-in Thermal Printer
China 12.1
Package Include:
1 x device
1 x Li-Battery
1 x Power line
1 x Earth wire
1 x User's Manual
1 x Blood oxygen probe (for SpO2, PR)
1 x Blood pressure cuff (for NIBP)
1 x ECG cable (for ECG, RESP)
1 x Temperature probe (for Temperature)
 
Specification
ECG 
Input3/5 wire ECG cable
Lead sectionI II III aVR, aVL, aVF, V
Gain selection*0.25, *0.5, *1, *2,Auto
Sweep speed6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
Heart rate range15-30bpm
Calibration±1mv
Accuracy±1bpm or ±1% (select the bigger data)
NIBP 
Test methodOscillometer
PhilosophyAdult, Pediatric and Neonate
Measurement typeSystolic Diastolic Mean
Measurement parameterAutomatic, Continuous measurement
Measurement method ManualmmHg or ±2%
SPO2 
Display TypeWaveform, Data
Measurement range0-100%
Accuracy±2% (between 70%-100%)
Pulse rate range20-300bpm
Accuracy±1bpm or ±2% (select the bigger data)
Resolution1bpm
2-Temperature (Rectal & Surface) 
Number of channels2 channels
Measurement range0-50ºC
Accuracy±0.1ºC
DisplayT1, T2
UnitºC/ºF selection
Refresh cycle1s-2s
Respiration (Impedance & Nasal Tube) 
Measurement type0-150rpm
Accuracy±1bm or ±5%, select the bigger data
Resolution1rpm