Vital signs monitor, arterial measurement, invasive patient monitor

Medical equipment, invasive patient monitor,  measure artery monitormedical monitor, hospital monitor , invasive monitorMONITOR (for measure artery, invasive)Vital Sign Monitor7" Standard 6 ParametersECG, NIBP,SpO2,RESP, TEMP,HR/PRParameters:SPO2Measurement range:        0~100%Resolut

Featured Products

Medical equipment, invasive patient monitor,  measure artery monitor
medical monitor, hospital monitor , invasive monitor


MONITOR (for measure artery, invasive)
Vital Sign Monitor

7" Standard 6 Parameters
ECG, NIBP,SpO2,RESP, TEMP,HR/PR

Parameters:
SPO2
Measurement range:        0~100%
Resolution:                1%
Accuracy:                 +2%(70-100%);0-69% unspecified
Alarm range               0~100%
Pluse Rate:                range:20~300bpm
Resolution:1bpm
Error:+1bpm or +2%,whichever is greater

NIBP
Method:                   Digital Automatic oscillometric
Operation mode :           Manual/Automatic/continuous
Auto measurement time:     Adjustable(1~480min)
Measurement Unit:         mmHg/Kpa selectable
Measurement types:         Systolic, Diastolic, Mean  
Measurement tange:
Range of Systolic pressure:   Adult: 40~270mmHg
Pediatric: 40~220mmHg
Neonate: 40~135mmHg
Range of mean pressure:     Adult: 20~235mmHg
Pediatric: 20~165mmHg
Neonate: 20~110mmHg
Range of diastolic pressure:   Adult: 10~215mmHg
Pediatric: 10~150mmHg
Neonate :10~100mmHg
Over-pressure protection:     Double safety protection
Resolution:                 1 mmHg
Alarm:                    Systolic.Diastolic,Mean


RESPIRATION
Method:                     Thoracic impedance
Measurement range:           Adult:7~120rpm;
Neonate/Pediatric:7~150rpm
Apnea alarm:                 YES,10~40s
Resolution:                   1rpm
Accuracy:                    +2rpm


TEMPERATURE
Compatible probe:             YSI or CYF
Measurement range:           5~50ºC
Resolution :                   0.1ºC
Accuracy:                    +0.1ºC
Refreshing time:               about 1
Average measuring time:        <10s


Miscellaneous

Satety:              
Safety level: Class I, type CF

Operation Environment
Temperature:     Working 0~+40ºC
Transportation and storage -20~+60ºC
Humidity:        working≤85%
Transportation and storage≤93%
Power:          AC 100-240,50/60Hz
Patient range:   Neonate, pediatric, adult patients


Accessories supplies
(1) 5 lead ECG cable  
(2) 1 spo2 probes  
(3) 1 NIBP prbe  
(4) 1 temp probe
(5)1 ground connecting liner  
(6) Chest electrode (10pcs/set)
Vital Sign Monitor, Measure Artery, Invasive Patient Monitor
Vital Sign Monitor, Measure Artery, Invasive Patient Monitor
Vital Sign Monitor, Measure Artery, Invasive Patient Monitor
Vital Sign Monitor, Measure Artery, Invasive Patient Monitor
Vital Sign Monitor, Measure Artery, Invasive Patient Monitor
Vital Sign Monitor, Measure Artery, Invasive Patient Monitor
Vital Sign Monitor, Measure Artery, Invasive Patient Monitor













 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours