Oxima3 portable multi-parameter patient vital signs monitor

Oxima3 Vital signs monitor three parameters: NIBP,SpO2 and TEMP NIBP: Measurement method: Oscillometric Range: Adult: 30mmHg~255mmHg Pediatric: 30mmHg~160mmHg Measurement unite: MmHg/kPa selectable Measurement mode: Manual Auto STAT Measurement Type: SYS DIA MAP Measurement interval in AUTO mod

Featured Products


Oxima3 Portable Patient Vital Sign Monitor with Multi-Parameter
Oxima3 Vital signs monitor three parameters: NIBP,SpO2 and TEMP
 
NIBP: 
Measurement method: Oscillometric 
Range: Adult: 30mmHg~255mmHg Pediatric: 30mmHg~160mmHg 
Measurement unite: MmHg/kPa selectable 
Measurement mode: Manual Auto STAT 
Measurement Type: SYS DIA MAP 
Measurement interval in AUTO mode: 1 2 3 5 10 15 20 30 45 60Min 
Measuring period in STAT mode: 5 Min 
Resolution: 1mmHg 
Over-pressure protection: Adult: 300mmHg Pediatric: 220mmHg 
 
SpO2: 
Range: 0 -100% 
Resolution: 1 % 
Accuracy: 2% (90~99%) 3% (70~89%) unspecified (< 70%) 
 
PR: 
Range: 30bpm~250bpm 
Resolution: 1bpm 
Accuracy: 2bpm 

TEMPERATURE 
Channel                                   2
Measuring and Alarm Range   0 ~ 50 °C
Resolution                                0.1°C
Accuracy                                 ±0.1°C
Actualization interval               about 1 Sec.
Average Time Constant          < 10 Sec.

IBP (optional)
Channel         2
Label              ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range 
                     ART                0~300mmHg
                     PA                  -6~120mmHg
                     CVP/RAP/LAP/ICP   -10~40mmHg
                     P1~P2              -10~300mmHg
Press Sensor
               Sensitivity              5 uV/V/mmHg
               Impedance             300-3000Ω
Resolution                           1mmHg
Accuracy                              ±2% or 1mmHg which great
Actualization Interval            about 1 Sec
 
Power Requirements: 
AC power adaptor 
Input: AC 100~240V 50/60Hz 0.7A 
Output: 5V 2.5A 
Internal battery 
Type: 2.8A build-in Li-ion rechargeable battery 
Operating Time: 6 hours of stand-by time with a full battery. 
Recharge time: 8 hours 
 
Oevice dimension: 210mm × 188mm × 107mm 
Net Weight: 1000g
Standard:
 
SpO2 Cable (Adult)   ........ 1Pcs
NIBP Cuff (Adult)   ............ 1Pcs
NIBP Tube(150cm)   ......... 1Pcs
Temp sensor.......................1pcs
Power Adapter .................. 1Pcs
Cleaning Cloth .................. 1Pcs

Options:
Cable Sp02 (Adult
Soft Sensor the shell)  Sp02 Cable ( Adult Soft Sensor the shell)
Sp02 Cable (Neonatal Soft Sensor) 
SpO2 Cable (Pediatric hard shell sensor)  
SpO2 Cable (Pediatric Soft shell sensor)
SpO2 Cable (Child finger clip)
SpO2 Cable (multi-site Y type)
SpO2 External Cable
NIBP Cuff (infant 8 - 14 cm 5/Bag)
NIBP Cuff (Child 13 - 20 cm 5/Bag)
NIBP Cuff (Small Adult 18 - 26 cm 5/Bag)
NIBP Cuff (Adult 26 - 35 cm 5/Bag)
NIBP Cuff (Adult Long 29 - 38 cm 5/Bag)
NIBP Cuff (Large Adult 32 - 42 cm 5/Bag)
NIBP Cuff (Large Adult Long 35 - 44 cm 5/Bag)
NIBP Cuff (Thigh 42 - 50 cm)
NIBP Tube 150cm
Paper Role
Thermal printer
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours