Product Description
Hospital Pediatrics Vital Sign Patient Monitor Portable Vital Signs Monitor
Introduction:
This equipment can monitor such parameters as ECG, RESP, SpO2, NIBP, and Dual- channel TEMP. It integrates parameter measuring module, display and recorder in one device to form a compact andportable device. At the same time, its built-in replaceable battery provides convenience for patient moving.
Features:
* Elegant appearance, clear marks, standard interface, oxyCRG SCREEN, trend graph, big characters, other BED observation, which are convenient for user.
* Be applicable for adult, pediatric and neonatal.
* Standard parameters of ECG, RESP, NIBP, SpO2 and dual-channel TEMP. IBP, CO2, Built-in printer, curving handle, moving bracket and hanging bracket are optional.
* Operation interface with Chinese and English. Finish all operations by keys and knobs. (Optional languages: French, German, Italian, Dutch, Portuguese, Turkish, Spanish, Poland.)
* 12.1'' color TFT LCD with high-resolution displays patient parameter and waveform, and alarm,
bed NO, clock, state and other information provided by the monitor synchronously.
* Monitoring contents, scan speed, volume and output contents can be set optionally.
* Storage of 480-hour trend data, and review of 40-second holographic waveform.
* Storage and review of 72-hour ECG waveform.
* Function of NIBP review, storage for up to 2400 NIBP data.
* Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability.
* Calculation of drug concentration.
* Network: connecting with central station, other Bed observation and software updating. Connection mode: wireless and wired.
* Built-in rechargeable battery for uninterrupted monitoring.
* Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).
* Analysis function for heart rate variability(HRV) (optional)
Performance:
ECG
| Lead Mode 3-lead and 5-lead are optional Lead Selection I, II, III, avR, avL, avF, V Wave 5-lead: 2 channels 3-lead: 1channel Gain ×2.5mm/mV, ×5.0mm/mV, ×10mm/mV, ×20mm/mV HR Measuring and Alarm Range Range 15 ~ 300 bpm Accuracy ±1% or ±1bpm, which is greater Alarm Accuracy ±2bpm Resolution 1 bpm |
CMRR
| Monitor ≥ 100 dB Surgery ≥ 100 dB Diagnosis ≥ 60 dB |
Bandwidth
| Surgery 1 ~ 20 Hz(+0.4dB,-3dB) Monitor 0.5 ~ 40 Hz(+0.4dB,-3dB) Diagnosis 0.05~75Hz(+0.4dB,-3dB); 76Hz~150Hz(+0.4dB,-4.5dB) Calibration Signal 1 mV (Vp-p), ±5% Accuracy |
ST Segment Monitoring | Measuring and Alarm Range -0.6 mV~ + 0.8 mV |
ARR | ARR Detecting Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY,R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC |
Alarm | Available |
Review | Available |
Scan Speed for ECG Waveform is adjustable | 12.5mm/s accuracy ±10% 25mm/s accuracy±10% 50mm/s accuracy±10% |
Respiration
| Method R-F(RA-LL) Impedance Differential Input Impedance >2.5 MΩ Measuring Impedance Range 0.3~5.0Ω Baseline Impedance Range 100Ω- 2500Ω Bandwidth 0.3 ~ 2.5 Hz |
Resp. Rate
| Measuring and Alarm Range 0~120rpm Resolution 1 rpm Measuring Accuracy ±2 rpm Alarm Accuracy ±3rpm Apnea Alarm 10 ~ 40 S |
NIBP | Method Oscillometry Mode Manual, Auto, continuous Measuring Interval in AUTO Mode 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 / 90/120/240/480/960 Min Measuring Period in Continuous Mode 5 Min Measuring and Alarm Range 10~270mmHg Alarm Type SYS, DIA, MEAN |
Resolution
| Pressure 1mmHg Cuff Pressure ±3 mmHg Accuracy ±10% or ±8mmHg, which is greater Over-pressure Protection: Adult Mode 315±10 mmHg Pediatric Mode 265±10 mmHg Neonatal Mode 155±10 mmHg |
SpO2 | Measuring Range 0 ~ 100 % Alarm Range 0 ~ 100 % Resolution 1 % Accuracy 70% ~ 100% ±2% 0% ~ 69% unspecified |
Pulse Rate(PR)
| Measuring and Alarm Range 0~250bpm Resolution 1bpm Measuring Accuracy ±2bpm or ±2%, which is greater Alarm Accuracy ±2bpm |
TEMP | Channel dual-channel Measuring and Alarm Range 0 ~ 50°C Resolution 0.1°C Accuracy ±0.1°C Actualization Interval about 1 Sec. Average Time Constant < 10 Sec. Alarm responding Time ≤2min |
EtCO2 | Method Sidestream or Mainstream Resolution for CO2: 0.1 mm Hg 0 to 69 mm Hg
Apnea Alarm Available |
IBP | Channel dual-channel Label ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and Alarm Range -50~350 mm Hg Accuracy ±2% or 1mm Hg, which is greater |
Physical Characteristic:
Dimension 310×140×263(mm)
Net weight 3.8Kg
Accessories:
1) Adult SpO2 probe(5-pin)
2) Adult NIBP cuff
3) Extending tube for blood pressure
4) ECG lead
5) ECG electrode
6) Temperature probe
7) Power cord
8) Thermal recording paper(optional)
9) User Manual
Packing and shipping
1. Package: double carton boxes
2. Port: Shenzhen China, Shanghai China
3. Delivery time: 3-5 working days after receipt of payment
Our Advantages:
Certificates:
Payment terms
T/T in advance, MoneyGram, Trade Assurance, Western Union, Escrow, Paypal, Credit Card!
Company information:
Exhibitions
Welcome to contact us!