High-quality 10.1-inch multi-parameter medical monitor, suitable for hospitalized newborns and adults.

PM10A Multi-Parameter Patient MonitorFeatures10.1 inch high resolution color TFT displayLightweight and portable design suitable for Ambulance, Emergency TransportThree Working Modes: Monitoring, Surgery and Diagnosis.Simple and friendly operating display interface.Multi-display modes suitable for different applications: St

Featured Products

PM10A Multi-Parameter Patient Monitor
High Quanlity 10.1 Inch Multi-Parameter Medical Patient Monitor for Neonatal Children Adults in Hospital.
High Quanlity 10.1 Inch Multi-Parameter Medical Patient Monitor for Neonatal Children Adults in Hospital.
High Quanlity 10.1 Inch Multi-Parameter Medical Patient Monitor for Neonatal Children Adults in Hospital.






Features
  1. 10.1 inch high resolution color TFT display
  2. Lightweight and portable design suitable for Ambulance, Emergency Transport
  3. Three Working Modes: Monitoring, Surgery and Diagnosis.
  4. Simple and friendly operating display interface.
  5. Multi-display modes suitable for different applications:
Standard Interface, Large font, ECG Standard Full Display, OXY , Trend Table, BP Trend.
  1. Built-in high capacity battery up to 3 hours of continuous work

Technique Specification
ECG
  1. Lead Mode: 5 Leads (I, II, III, AVR, AVL,AVF, V)
  2. Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV
  3. Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)
Resolution: 1 BPM
Accuracy: ±1%
Sensitivity >200 uV(Peak to peak)
  1. ST measurement range: -2.0 ~ +2.0 mV
Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater
Other Range: unspecified
  1. Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
  2. Bandwidth:
    1. Diagnostic: 0.05~130 Hz
    2. Monitor: 0.5~40 Hz
    3. Surgery: 1~20 Hz
                        
SPO2
  1. Measuring Range: 0 ~ 100 %
  2. Resolution: 1%
  3. Accuracy: 70% ~ 100% (±2 %)
  4. Pulse Rate: 20-250 BPM
  5. Resolution: 1 BPM
  6. Accuracy: ±3 BPM


NIBP
  1. Method: Oscillometry
  2. Measure mode: Manual, Auto, STAT
  3. Unit: mmHg, kPa
  4. Measure and alarm range:
    1. Adult Mode
          1. SYS 40 ~ 280 mmHg
          2. DIA 10 ~ 225 mmHg
          3. MEAN 20 ~ 240 mmHg
    2. Pediatric Mode
          1. SYS  40 ~ 220 mmHg
          2. DIA  10 ~ 160 mmHg
          3. MEAN 20 ~ 170 mmHg
    3. Neonatal Mode
          1. SYS 40 ~ 135 mmHg
          2. DIA 10 ~ 100 mmHg
          3. MEAN  20 ~ 110 mmHg
  5. Resolution: 1mmHg
  6. Accuracy: ±5mmHg

RESP
  1. Method: Impedance between RA-LL or RALA
  2. Measurement Range:
Adult: 10 ~ 120 BrPM
Neonatal / Pediatric: 7 ~ 150 BrPM
  1. Resolution: 1 BrPM
  2. Accuracy: ±2 BrPM

TEMP
  1. Measure and Alarm Range: 0 ~ 50 °C
  2. Resolution: 0.1°C
  3. Accuracy: ±0.1°C

Standard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PR

Optinal Parameters:
  1. Central monitoring system
  2. Dual IBP
  3. Etco2
  4. 12-lead ECG;
  5. Nellcor SpO2;
  6. Sun Tech NIBP.

Standard Configuration:
No.ItemQty
1Main Unit1
25-lead ECG cable1
3Disposable ECG Electrode5
4Adult Spo2 probe1
5Adult NIBP cuff1
6NIBP extension tube1
7Temperature probe1
8Power Cable1
9User Manual1
10Fuse3

Packing:
  1. Single package size: 34.7*20.7*27.7cm
  2. Single gross weight: 2.8 KG
  3. 6 unit per carton, package size: 65*36.2*59cm, total gross weight 18 KG




High Quanlity 10.1 Inch Multi-Parameter Medical Patient Monitor for Neonatal Children Adults in Hospital.
High Quanlity 10.1 Inch Multi-Parameter Medical Patient Monitor for Neonatal Children Adults in Hospital.

High Quanlity 10.1 Inch Multi-Parameter Medical Patient Monitor for Neonatal Children Adults in Hospital.




 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours