CONTEC CMS9000 hospital medical patient monitor multi-parameter good price
Model: CMS9000 Brand:CONTEC
Features
- Color TFT Screen, waveform up to 8 channels
- Light and portable with build-in rechargeable battery
- UP to 10 kinds of monitor parameters
- Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis
- 72 hour storage and review of trend grams and tables, 40 second review of olographic wavefo RMS.
- Built-in recorder(option)
- All-round monitor of adult, pediatric and neonatal.
- Electrosurgical unit and defibrillation protected
- Standard parameters: ECG, NIBP, SpO2, Respiration, Temperature, Pulse rate
- Option parameters: EtCO2, CO, IBP, Thermal Printer
ECG
- 5-lead or 3-lead selectable
- Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
- Lead selection: I; II; III; AvR; AvL; AvF; Vx; CAL
- Gain selection: 12.5mm/s, 25mm/s, 50mm/s
- Accuracy: ± 1bpm or ± 1%, whichever is greater
- Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
- Calibration signal: 1mV± 5%
- Operation modes: Diagnostic, Monitor, Surgery
- Alarm range: Adult: 15-300bpm
- Pediatric/Neonatal: 15-350bpm
- Alarm range: -2.0mV~2.0mV
- S-T detection: YES, Arrhythmia analysis: YES
- Alarm: YES, audible and visual alarm, alarm events recallable
NIBP
- Method: Oscillometry
- Operation modes: Manual/Automatic/STAT
- Measurement unit: MmHg/KPa selectable
- Measurement types: Systolic, Diastolic, Mean
- Measurement range: Adult: 10-270mmHg
- Over-pressure protection: YES
- Resolution: 1mmHg
- Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10
- Alarm: Systolic, Diastolic, Mean
SpO2
- Measurement range: 0-100%
- Accuracy: ± 2digit (70~100%);
- 0~69% unspecified
- Alarm range: 0-100%
Respiration
- Method: RA-LL impedance
- Pediatric/Neonatal: 6-150rpm
- Alarm range: Adult: 6-120rpm
- Pediatric/Neonatal: 6-150rpm
- Apnea alarm: YES
Temperature
- Resolution: 0.1
- Channel: Dual-channel
- Alarm range: 0-50
Option:
EtCO2
- Measurement Mode: Side-stream or mainstream
- Measurement range: EtCO2: 0-99mmHg
- Accuracy: CO2 concentration
- Apnea alarm: YES
IBP
- Channel: 2 channels
- Pressure transducer: Sensitivity: 5( mV/V/mmHg)
- Transducer sites: ART, PA, CVP, RAP, LAP, ICP
- Alarm range: -10~300mmHg
-Patient Monitoring
-ECG machine(Electrocardiograph)/Holter ECG/Stress test ECG,
-EEG,
-Ultrasound Imaging,Pocket fetal doppler,fetal monitor,
-Blood pressure Monitor(ABPM),
-spirometer
-infusion/syringe Pump
-Digital Stethscope
-In-Vitro Diagnostics
-simulator
-Veterinary products
Model: CMS9000 Brand:CONTEC
Features
- Color TFT Screen, waveform up to 8 channels
- Light and portable with build-in rechargeable battery
- UP to 10 kinds of monitor parameters
- Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis
- 72 hour storage and review of trend grams and tables, 40 second review of olographic wavefo RMS.
- Built-in recorder(option)
- All-round monitor of adult, pediatric and neonatal.
- Electrosurgical unit and defibrillation protected
- Standard parameters: ECG, NIBP, SpO2, Respiration, Temperature, Pulse rate
- Option parameters: EtCO2, CO, IBP, Thermal Printer
ECG
- 5-lead or 3-lead selectable
- Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
- Lead selection: I; II; III; AvR; AvL; AvF; Vx; CAL
- Gain selection: 12.5mm/s, 25mm/s, 50mm/s
- Accuracy: ± 1bpm or ± 1%, whichever is greater
- Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
- Calibration signal: 1mV± 5%
- Operation modes: Diagnostic, Monitor, Surgery
- Alarm range: Adult: 15-300bpm
- Pediatric/Neonatal: 15-350bpm
- Alarm range: -2.0mV~2.0mV
- S-T detection: YES, Arrhythmia analysis: YES
- Alarm: YES, audible and visual alarm, alarm events recallable
NIBP
- Method: Oscillometry
- Operation modes: Manual/Automatic/STAT
- Measurement unit: MmHg/KPa selectable
- Measurement types: Systolic, Diastolic, Mean
- Measurement range: Adult: 10-270mmHg
- Over-pressure protection: YES
- Resolution: 1mmHg
- Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10
- Alarm: Systolic, Diastolic, Mean
SpO2
- Measurement range: 0-100%
- Accuracy: ± 2digit (70~100%);
- 0~69% unspecified
- Alarm range: 0-100%
Respiration
- Method: RA-LL impedance
- Pediatric/Neonatal: 6-150rpm
- Alarm range: Adult: 6-120rpm
- Pediatric/Neonatal: 6-150rpm
- Apnea alarm: YES
Temperature
- Resolution: 0.1
- Channel: Dual-channel
- Alarm range: 0-50
Option:
EtCO2
- Measurement Mode: Side-stream or mainstream
- Measurement range: EtCO2: 0-99mmHg
- Accuracy: CO2 concentration
- Apnea alarm: YES
IBP
- Channel: 2 channels
- Pressure transducer: Sensitivity: 5( mV/V/mmHg)
- Transducer sites: ART, PA, CVP, RAP, LAP, ICP
- Alarm range: -10~300mmHg
Standard six parameters | ECG,SPO2,RESP,TEMP,NIBP,PULSE RATE |
Optional | ETCO2,CO,IBP,Thermal Printer |
Screen size | 12.1 inch |
Size | 310*140*263mm |
Net Weight | 3.8kg |
Accessories | 1) Adult SpO2 probe(5-pin) |
2) Adult NIBP cuff | |
3) Extending tube for blood pressure | |
4) ECG lead | |
5) ECG electrode | |
6) Temperature probe | |
7) Power cord | |
8) Thermal recording paper(optional) | |
9) User Manual |
-TELEMEDICINE products
-Pulse oximeter-Patient Monitoring
-ECG machine(Electrocardiograph)/Holter ECG/Stress test ECG,
-EEG,
-Ultrasound Imaging,Pocket fetal doppler,fetal monitor,
-Blood pressure Monitor(ABPM),
-spirometer
-infusion/syringe Pump
-Digital Stethscope
-In-Vitro Diagnostics
-simulator
-Veterinary products