12.1 inch mother and baby monitor

12.1 inch Maternal and Baby MonitorMC-9000Feature12.1" color TFT screen Multi‐channel display Big font interfaceST and arrhythmia analysisDrug dose calculation and titration tableOxyCRG dynamic view displayRespiration monitoring with apnea alarmsAlarm review, arrhythmia review Patien

Featured Products

12.1 inch Maternal and Baby Monitor
MC-9000

12.1 Inch Maternal and Baby Monitor

Feature

12.1" color TFT screen 
Multichannel display 
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
Alarm review, arrhythmia review 
Patient info. Input 
Antidefibrillation design
NIBP over pressure protection
Plugin rechargeable battery, AC/DC available. 
Supporting wire or wireless network.

Technical Specifications

 
ECG
 
Lead Mode                                      5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 
Lead selection                                 I, II, III, avR, avL, avF, V
Wavef orm                                       2 ch
Lead mode                                      3 Leads ( R, L, F or RA, LA, LL) 
Lead selection                                  I, II, III,
Wave form                                        1 ch
Gain                                                  2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto
 
HR and Alarm Range                        Adult    15 ~ 300 bpm
                                                         Neo/Ped    15 ~ 350 bpm
Accuracy                                          ±1% or±1bpm, which is greater
Resolution                                       1 bpm 
Sensitivity                                        > 200 (uVp-p) 
Differential Input Impedance           > 5 MΩ
 
CMRR                                            Monitor > 105 dB 
                                                      Operation > 105 dB 
                                                      Diagnosis > 85 dB
Electrode offset potential              ±300mV 
Leakage Current                          < 10 uA
Baseline Recovery                       < 3 S After Defi. 
ECG Signal Range                       ±8 m V ( Vp-p ) 
 
Bandwidth                                    Surgery    1 ~ 20 Hz
                                                     Monitor     0.5 ~ 40 Hz
                                                     Diagnostic  0.05 ~ 130 Hz
Calibration Signal                         1 (mVp-p),  Accuracy:5%
ST Segment Monitoring Range    Measure and Alarm -2.0 ~ +2.0 mV
 
ARR Detecting                             Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T,                                                                VT>2,BRADY, MISSED BEATS,PNP, PNC,Alarm Available,Review Available
 
 
Respiration
 
Method                                          Impedance between R-F(RA-LL)
Differential Input Impedance         > 2.5 MΩ
Measuring Impedance Range       0.3~3 Ω
Base line Impedance Range         200~4 KΩ
Bandwidth                                     0.1~2.5Hz
Resp. Rate                                   Measuring and Alarm Range
                                                      Adult 0 ~ 120 Brpm 
                                                     Neo/Ped 0 ~ 150 Brpm 
                                                     Resolution 1 Brpm 
                                                     Accuracy ±2 Brpm
 
Apnea Alarm                                10 ~ 40 S
 
 
 
 
 
NIBP 
 
Method                                        Oscillometric
Mode                                           Manual, Auto, STAT                        
Measuring Interval in AUTO Mode  1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode   5 Min
Pulse Rate Range                         40 ~ 240 bpm
Alarm Type                                    SYS, DIA, MEAN
 
Measuring and alarm range     Adult Mode
                                                     SYS 40 ~ 270 mmHg 
                                                     DIA 10 ~ 215 mmHg 
                                                     MEAN 20 ~ 235 mmHg
                                                Pediatric Mode
                                                    SYS 40 ~ 200 mmHg 
                                                    DIA 10 ~ 150 mmHg 
                                                    MEAN 20 ~ 165 mmHg
                                               Neonatal Mode
                                                   SYS 40 ~ 135 mmHg 
                                                   DIA 10 ~ 100 mmHg 
                                                   MEAN 20 ~ 110 mmHg
Resolution                                 1mmHg
 
Accuracy                                    Maximum Mean error ±5mmHg
                                                   Maximum Standard deviation ±8mmHg
Overpressure Protection            Adult Mode 297±3 mmHg 
                                                  Pediatric Mode 240±3 mmHg 
                                                  Neonatal Mode 147±3 mmHg
 
SpO2
Measuring Range                      0 ~ 100 % 
Alarm Range                              0 ~ 100 % 
Resolution                                  1 %
Accuracy                                    70% ~ 100%  2 %
                                                  0%  ~  69% unspecified
Actualization intervalabout         1 Sec. 
Alarm Delay                               10 Sec.
Pulse Rate                                 Measuring and Alarm Range 20~300 bpm
                                                   Resolution       1bpm
                                                   Accuracy ±3bpm
                                  
 
 
TEMP
 
Channel                                       2
Measuring and Alarm Range       0 ~ 50 ºC
Resolution                                   0.1 ºC
Accuracy                                    ±0.2 ºC
Actualization intervalabout          1 Sec.
Average Time Constant              < 10 Sec.
 
 
IBP
 
Label                                           ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range        ART 0 ~ 300 mmHg 
                                                    PA -6 ~ 120 mmHg
                                                    CVP/RAP/LAP/ICP-10 ~ 40 mmHg
                                                    P1 / P2-10 ~ 300 mmHg 
 
 
Press Sensor                              Sensitivity 5  uV/V/mmHg
                                                    Impedance 300-3000Ω
 
Resolution                                  1 mmHg
Accuracy                                    ±2% or 1mmHg which is greater
Actualization interval                  about 1 secretary
 

Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder